{"id":51170,"date":"2026-01-01T17:58:07","date_gmt":"2026-01-01T17:58:07","guid":{"rendered":"https:\/\/medqpharmaceuticalsupplies.co.za\/?post_type=product&#038;p=51170"},"modified":"2026-01-01T17:59:13","modified_gmt":"2026-01-01T17:59:13","slug":"cs-826-series-professional-bench-top-spectrophotometer","status":"publish","type":"product","link":"https:\/\/medqpharmaceuticalsupplies.co.za\/?product=cs-826-series-professional-bench-top-spectrophotometer","title":{"rendered":"CS-826 Series Professional Bench-top Spectrophotometer"},"content":{"rendered":"<table border=1 width=1118 cellspacing=0 cellpadding=2>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>CS-820P<\/td>\n<td>CS-821N<\/td>\n<td>CS-826<\/td>\n<\/tr>\n<tr>\n<td rowspan=3>Lighting\/measuring conditions<\/td>\n<td colspan=3>Reflection\uff1ad\/8\uff08diffuse illumination\uff0c8\u00b0direction reception\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=3>SCI\uff08Contains specular reflected light\uff09\/ SCE\uff08not contain specular reflected light\uff09measure at same time.<\/p>\n<p>Compliance standards\uff1aCIE No.15\u3001GB\/T 3978\u3001GB 2893\u3001GB\/T 18833\u3001ISO7724\/1\u3001DIN5033 Teil7\u3001<\/p>\n<p>JIS Z8722 Condition C\u3001ASTM E1164\u3001ASTM-D1003-07<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=3>Transmission\uff1ad\/0\uff08diffuse illumination, vertical reception\uff09<\/td>\n<\/tr>\n<tr>\n<td>Sensor<\/td>\n<td colspan=1 rowspan=1>Silicon Photodiode Array<\/td>\n<td colspan=2 rowspan=1 valign=top>Dual column high precision CMOS array sensor<\/td>\n<\/tr>\n<tr>\n<td>Automatic calibration<\/td>\n<td colspan=1 rowspan=1>\u2013<\/td>\n<td colspan=2 rowspan=1 valign=top>\u221a\uff08Can greatly improve the long-term repeatability of the instrument\uff09<\/td>\n<\/tr>\n<tr>\n<td>Integrating sphere diameter<\/td>\n<td colspan=3>152mm<\/td>\n<\/tr>\n<tr>\n<td>Wavelength range<\/td>\n<td colspan=3>360nm-780nm<\/td>\n<\/tr>\n<tr>\n<td>Wavelengthinterval<\/td>\n<td colspan=3>10nm<\/td>\n<\/tr>\n<tr>\n<td>Reflectance measurement range<\/td>\n<td colspan=3>0-200%\uff0cresolution 0.01%<\/td>\n<\/tr>\n<tr>\n<td>Lighting source<\/td>\n<td colspan=3>Pulsed xenon lamps andLED<\/td>\n<\/tr>\n<tr>\n<td>Ultraviolet measurement<\/td>\n<td colspan=3>IncludesUV\u3001400nmcutoff\u3001420nmcutoff\u3001460nmcutoff<\/td>\n<\/tr>\n<tr>\n<td>Measuring time<\/td>\n<td colspan=3>Single mode<2s<\/td>\n<\/tr>\n<tr>\n<td>Lighting\/measuring calibers<\/td>\n<td colspan=3>Reflection\uff1aXLAV \u03a625.4mm\/\u03a630mm\uff1bLAV\u03a615mm\/\u03a618mm\uff1bMAV\u03a68mm\/\u03a611mm\uff1bSAV\u03a63mm\/\u03a66mm<\/p>\n<p>Users can customize the calibre, and the calibre switch is automatically recognized<\/p>\n<p>Transmission\uff1a\u03a617mm\/\u03a625mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Transmission measurement specification<\/td>\n<td colspan=3>Sample height and thickness:height is not limited, thickness\u226450mm<\/td>\n<\/tr>\n<tr>\n<td>Repeatability **<\/td>\n<td>\u0394E*ab\u22640.015\uff0cSpectral reflection\/transmittance \u22640.1%<\/td>\n<td colspan=2>\u0394E*ab\u22640.01\uff0cSpectral reflection\/transmittance \u22640.1%<\/td>\n<\/tr>\n<tr>\n<td>Inter-Instrument Agreement**<\/td>\n<td>XLAV \u0394E*ab 0.25<\/td>\n<td colspan=2 rowspan=1>XLAV \u0394E*ab 0.2<\/td>\n<\/tr>\n<tr>\n<td>Long-term repeatability***<\/td>\n<td colspan=3>XLAV chroma value:standard deviation \u0394E*ab within 0.1\uff08under constant temperature conditions,the white correction plate is measured every hour within 24 hours)<\/td>\n<\/tr>\n<tr>\n<td>Standard observer<\/td>\n<td colspan=3>2\u00b0Standard observer and 10\u00b0Standard observer<\/td>\n<\/tr>\n<tr>\n<td>Viewing light source<\/td>\n<td colspan=3>A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83,TL84,ID50,ID65,<\/p>\n<p>LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Language<\/td>\n<td colspan=3>Simplified Chinese,English, Traditional Chinese, Russian, Spanish, Portuguese, Japanese, Thai, Korean,German, French, Polish<\/td>\n<\/tr>\n<tr>\n<td>Display content<\/td>\n<td colspan=3>Spectral data,Spectrogram, chromaticity data, chromaticity Data, chromaticity map, Pass\/Fail judgment, Simulation color, Color evaluation, fog, liquid chromaticity, Color bias<\/td>\n<\/tr>\n<tr>\n<td>Color space<\/td>\n<td colspan=3>CIE LAB,CIE LUV,LCh,Hunter Lab,Yxy,XYZ,Musell,s-RGB,\u03b2xy<\/td>\n<\/tr>\n<tr>\n<td>Chroma index<\/td>\n<td colspan=3>WI(ASTM E313-20,ASTM E313-73,CIE,AATCC,Hunter,Taube,Berger Stensby),YI(ASTM D1925,ASTM E313-20,ASTM E313-73),<\/p>\n<p>Tint(ASTM E313-20),Isochromatic index Milm,color fastness,color changing fastness,ISO brightness,R457,A density,T density,E density,M density,APHA\/Hazen\/<\/p>\n<p>Pt-Co((platinum-cobalt index),Gardner(Gardner Index),Saybolt(SeibertIndex),Astm color,fog, total transmittance, covering power, force, intensity<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Color difference formula<\/td>\n<td colspan=3>\u0394E*ab,\u0394E*CH,\u0394E*uv,\u0394E*cmc,\u0394E*94,\u0394E*00,\u0394Eab(Hunter),555color tone classification<\/td>\n<\/tr>\n<tr>\n<td>Storage<\/td>\n<td colspan=3>8GB<\/td>\n<\/tr>\n<tr>\n<td>Screen size<\/td>\n<td colspan=3>7-inch capacitive touch screen<\/td>\n<\/tr>\n<tr>\n<td>Operating system<\/td>\n<td colspan=3>Android<\/td>\n<\/tr>\n<tr>\n<td>Power source<\/td>\n<td colspan=3>Dc regulated power supply<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature and humidity<\/td>\n<td colspan=3>5\uff5e40\u00b0C,relative humidity 80%(35\u00b0C)below no condensation<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature and humidity<\/td>\n<td colspan=3>-20\uff5e45\u00b0C,relative humidity 80%(35\u00b0C)below no condensation<\/td>\n<\/tr>\n<tr>\n<td>Accessories<\/td>\n<td colspan=3>Power adapter,USB cable, transmission fixture, software U disk, black cavity, white board, green board,30mm aperture,<\/p>\n<p>18mm aperture,11mm aperture,6mm aperture,support table,cuvette,damping handle<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Port<\/td>\n<td colspan=3>RS-232\u3001USB\u3001USB-B\u3001Bluetooth<\/td>\n<\/tr>\n<tr>\n<td>Others<\/td>\n<td colspan=3>The instrument can be measured sideways,up and down (using accessories); Automatic temperatureand humidity compensation function; PC side software save sample image function<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u203b\u203bBased on 23\u00b0C,the average value of XLAV aperture measurement of 12 swatches of BCRA Series is measured<\/p>\n<p>\u203b\u203b\u203bXLAV chromatic value:standard deviation \u0394E*ab within 0.1\uff080\u2103-40\u2103 Arbitrary temperature variation\uff09<\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"product_desc\">CS-826 is a high-precision, high-consistency color measurement desktop spectrophotometer; advanced process technology, powerful data processor, so that the CS-826 in the color measurement of black objects with excellent stability; automatic calibration of the instrument to ensure the stability of long-term measurements; improve the high stability of the UV light source, providing a stable fluorescence measurement of the markers, and the instrument measurement data can be with the United States The instrument\u2019s measurement data has excellent consistency with other competitors in the U.S., Japan, and Europe.<\/div>\n","protected":false},"featured_media":51212,"template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[35316],"product_tag":[11602],"class_list":["post-51170","product","type-product","status-publish","has-post-thumbnail","product_cat-meter","product_tag-spectrocolorimeterspectrophotometer","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=\/wp\/v2\/product\/51170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=\/wp\/v2\/media\/51212"}],"wp:attachment":[{"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=51170"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=51170"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=51170"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=51170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}