{"id":50376,"date":"2026-01-01T17:39:17","date_gmt":"2026-01-01T17:39:17","guid":{"rendered":"https:\/\/medqpharmaceuticalsupplies.co.za\/?post_type=product&#038;p=50376"},"modified":"2026-01-01T17:40:16","modified_gmt":"2026-01-01T17:40:16","slug":"multiparameter-photometer-ph-meter","status":"publish","type":"product","link":"https:\/\/medqpharmaceuticalsupplies.co.za\/?product=multiparameter-photometer-ph-meter","title":{"rendered":"Multiparameter Photometer &#038; pH Meter"},"content":{"rendered":"<div id=attachment_4069 style=width: 310px class=wp-caption alignnone><img decoding=async aria-describedby=caption-attachment-4069 title=multiparameter photometer &#038; ph meter class=size-medium wp-image-4069 lazyloaded data-src=https:\/\/www.chemicalplus.co.za\/wp-content\/uploads\/2020\/07\/multiparameter-photometer-ph-meter.jpg.webp alt=multiparameter photometer &#038; ph meter width=300 height=300 src=https:\/\/www.chemicalplus.co.za\/wp-content\/uploads\/2020\/07\/multiparameter-photometer-ph-meter.jpg.webp style=--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/300;><noscript><img decoding=async aria-describedby=caption-attachment-4069 title=multiparameter photometer &#038; ph meter class=size-medium wp-image-4069 src=https:\/\/www.chemicalplus.co.za\/wp-content\/uploads\/2020\/07\/multiparameter-photometer-ph-meter.jpg.webp alt=multiparameter photometer &#038; ph meter width=300 height=300 \/><\/noscript><\/p>\n<p id=caption-attachment-4069 class=wp-caption-text>Multiparameter Photometer &#038; pH Meter for Water Conditioning- HI83308-02<\/p>\n<\/div>\n<p>HI83308 is a compact, multiparameter photometer for use in water conditioning applications.<\/p>\n<p>The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.<\/p>\n<p>This meter has 23 different programmed methods measuring 15 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Water conditioning parameters include fluoride, chlorine, ammonia, manganese, copper, iron, silver and zinc.<\/p>\n<p>To save valuable laboratory benchtop space, the HI83308 doubles as a professional pH meter with its digital pH\/temperature electrode input. Now one meter can be used for both photometric and pH measurements.<\/p>\n<div>\n<h3 class=spec-header><\/h3>\n<table id=product-attribute-specs-table-1 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>pH Range<\/th>\n<td class=data last>Photometer: 6.5 to 8.5 pH<br \/>\npH electrode: -2.00 to 16.00 pH<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>pH Resolution<\/th>\n<td class=data last>Photometer: 0.1 pH<br \/>\npH electrode: 0.01 pH<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>pH Accuracy<\/th>\n<td class=data last>Photometer: \u00b10.1 pH<br \/>\npH electrode: \u00b10.01 pH<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>pH Calibration<\/th>\n<td class=data last>Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>pH Temperature Compensation<\/th>\n<td class=data last>Automatic (-5.0 to 100.0\u00a0oC; 23.0 to 212.0\u00a0oF); limits reduced based on the pH electrode used<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>pH CAL Check (electrode diagnostics)<\/th>\n<td class=data last>clean electrode and check buffer\/check probe displayed during calibration<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>pH Method<\/th>\n<td class=data last>Photometer: phenol red<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>pH-mV Range<\/th>\n<td class=data last>\u00b11000 mV<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>pH-mV Resolution<\/th>\n<td class=data last>0.1 mV<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>pH-mV Accuracy<\/th>\n<td class=data last>\u00b10.2 mV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Oxygen, Dissolved<\/h3>\n<table id=product-attribute-specs-table-2 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Oxygen, Dissolved Range<\/th>\n<td class=data last>0.0 to 10.0 mg\/L (as O2)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Oxygen, Dissolved Resolution<\/th>\n<td class=data last>0.1 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Oxygen, Dissolved Accuracy<\/th>\n<td class=data last>\u00b10.4 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Oxygen, Dissolved Method<\/th>\n<td class=data last>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Absorbance<\/h3>\n<table id=product-attribute-specs-table-3 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Absorbance Range<\/th>\n<td class=data last>0.000 to 4.000 Abs<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Absorbance Resolution<\/th>\n<td class=data last>0.001 Abs<\/td>\n<\/tr>\n<tr class=last odd>\n<th class=label>Absorbance Accuracy<\/th>\n<td class=data last>+\/-0.003Abs @ 1.000 Abs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Ammonia<\/h3>\n<table id=product-attribute-specs-table-4 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Ammonia Range<\/th>\n<td class=data last>Low Range: 0.00 to 3.00 mg\/L<br \/>\nMedium Range: 0.00 to 10.00 mg\/L<br \/>\nHigh Range: 0.0 to 100.0 mg\/L<br \/>\n(all as NH3-N)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Ammonia Resolution<\/th>\n<td class=data last>0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Ammonia Accuracy<\/th>\n<td class=data last>Low Range: \u00b10.04 mg\/L \u00b14% of reading<br \/>\nMedium Range: \u00b10.05 mg\/L \u00b15% of reading<br \/>\nHigh range: \u00b10.5 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Ammonia Method<\/th>\n<td class=data last>Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Chlorine<\/h3>\n<table id=product-attribute-specs-table-5 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Free Chlorine Range<\/th>\n<td class=data last>0.00 to 5.00 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Free Chlorine Resolution<\/th>\n<td class=data last>0.01 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Free Chlorine Accuracy<\/th>\n<td class=data last>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Total Chlorine Range<\/th>\n<td class=data last>0.00 to 5.00 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Total Chlorine Resolution<\/th>\n<td class=data last>0.01 mg\/L<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Total Chlorine Accuracy<\/th>\n<td class=data last>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=last odd>\n<th class=label>Chlorine Method<\/th>\n<td class=data last>Adaptation of the EPA 330.5 DPD method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Copper<\/h3>\n<table id=product-attribute-specs-table-6 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Copper Range<\/th>\n<td class=data last>Low Range: 0.000 to 1.500 mg\/L (as Cu2+)<br \/>\nHigh range: 0.00 to 5.00 mg\/L (as Cu2+)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Copper Resolution<\/th>\n<td class=data last>0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Copper Accuracy<\/th>\n<td class=data last>Low Range: \u00b10.01 mg\/L \u00b15% of reading<br \/>\nHigh Range \u00b10.02 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Copper Method<\/th>\n<td class=data last>Adaptation of the EPA bicinchoninate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Fluoride<\/h3>\n<table id=product-attribute-specs-table-7 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Fluoride Range<\/th>\n<td class=data last>0.00 to 2.00 mg\/L (as F-)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Fluoride Resolution<\/th>\n<td class=data last>0.01 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Fluoride Accuracy<\/th>\n<td class=data last>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Fluoride Method<\/th>\n<td class=data last>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Iron<\/h3>\n<table id=product-attribute-specs-table-8 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Iron Range<\/th>\n<td class=data last>Low Range: 0.000 to 1.600 mg\/L (as Fe)<br \/>\nHigh Range: 0.00 to 5.00 mg\/L (as Fe)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Iron Resolution<\/th>\n<td class=data last>0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Iron Accuracy<\/th>\n<td class=data last>Low Range: \u00b10.01 mg\/L \u00b18% of reading<br \/>\nHigh Range: \u00b10.04 mg\/L \u00b12% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Iron Method<\/th>\n<td class=data last>Low Range: Adaptation of the TPTZ Method<br \/>\nHigh Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Manganese<\/h3>\n<table id=product-attribute-specs-table-9 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Manganese Range<\/th>\n<td class=data last>Low Range: 0 to 300 ?g\/L (as Mn)<br \/>\nHigh Range: 0.0 to 20.0 (as Mn)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Manganese Resolution<\/th>\n<td class=data last>1 ?g\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Manganese Accuracy<\/th>\n<td class=data last>Low Range: \u00b110 ?g\/L \u00b13% of reading<br \/>\nHigh Range: \u00b10.2 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Manganese Method<\/th>\n<td class=data last>Low Range: Adaptation of the PAN Method<br \/>\nHigh Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Molybdenum<\/h3>\n<table id=product-attribute-specs-table-10 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Molybdenum Range<\/th>\n<td class=data last>0.0 to 40.0 mg\/L (as Mo6+)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Molybdenum Resolution<\/th>\n<td class=data last>0.1 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Molybdenum Accuracy<\/th>\n<td class=data last>\u00b10.3 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Molybdenum Method<\/th>\n<td class=data last>Adaptation of the mercaptoacetic acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Nickel<\/h3>\n<table id=product-attribute-specs-table-11 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Nickel Range<\/th>\n<td class=data last>Low Range: 0.000 to 1.000 mg\/L (as Ni)<br \/>\nHigh Range: 0.00 to 7.00 g\/L (as Ni)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Nickel Resolution<\/th>\n<td class=data last>0.001 mg\/L; 0.01 g\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Nickel Accuracy<\/th>\n<td class=data last>Low range: \u00b10.010 mg\/L \u00b17% of reading<br \/>\nHigh Range: \u00b10.07 g\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Nickel Method<\/th>\n<td class=data last>Low Range: Adaptation of the PAN method<br \/>\nHigh Range: Adaptation of the photometric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Nitrate<\/h3>\n<table id=product-attribute-specs-table-12 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Nitrate Range<\/th>\n<td class=data last>0.0 to 30.0 mg\/L (as NO3\u2013 N)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Nitrate Resolution<\/th>\n<td class=data last>0.1 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Nitrate Accuracy<\/th>\n<td class=data last>\u00b10.5 mg\/L \u00b110% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Nitrate Method<\/th>\n<td class=data last>Adaptation of the cadmium reduction method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Phosphate<\/h3>\n<table id=product-attribute-specs-table-13 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Phosphate Range<\/th>\n<td class=data last>Freshwater<br \/>\nLow Range: 0.00 to 2.50 mg\/L (as PO43-)<br \/>\nHigh range: 0.0 to 30.0 mg\/L(as PO43-)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Phosphate Resolution<\/th>\n<td class=data last>0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Phosphate Accuracy<\/th>\n<td class=data last>Low Range: \u00b10.04 mg\/L \u00b14% of reading<br \/>\nHigh Range: \u00b11 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Phosphate Method<\/th>\n<td class=data last>Low Range: Adaptation of the Ascorbic Acid method<br \/>\nHigh Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Silica<\/h3>\n<table id=product-attribute-specs-table-14 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Silica Range<\/th>\n<td class=data last>0.00 to 2.00 mg\/L (as SiO2)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Silica Resolution<\/th>\n<td class=data last>0.01 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Silica Accuracy<\/th>\n<td class=data last>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Silica Method<\/th>\n<td class=data last>Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Silver<\/h3>\n<table id=product-attribute-specs-table-15 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Silver Range<\/th>\n<td class=data last>0.000 to 1.000 mg\/L (as Ag)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Silver Resolution<\/th>\n<td class=data last>0.001 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Silver Accuracy<\/th>\n<td class=data last>\u00b10.020 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Silver Method<\/th>\n<td class=data last>Adaptation of the PAN method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>Zinc<\/h3>\n<table id=product-attribute-specs-table-16 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Zinc Range<\/th>\n<td class=data last>0.00 to 3.00 mg\/L (as Zn)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Zinc Resolution<\/th>\n<td class=data last>0.01 mg\/L<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Zinc Accuracy<\/th>\n<td class=data last>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=last even>\n<th class=label>Zinc Method<\/th>\n<td class=data last>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=spec-header><\/h3>\n<h3 class=spec-header>General Meter<\/h3>\n<table id=product-attribute-specs-table-17 class=data-table>\n<colgroup>\n<col width=25%>\n<col><\/colgroup>\n<tbody>\n<tr class=first odd>\n<th class=label>Input Channels<\/th>\n<td class=data last>1 pH electrode input and 4 photometer wavelengths<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>pH Electrode<\/th>\n<td class=data last>digital pH electrode (not included)<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Logging Type<\/th>\n<td class=data last>log on demand with user name and sample ID optional input<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Logging Memory<\/th>\n<td class=data last>1000 readings<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Connectivity<\/th>\n<td class=data last>USB-A host for flash drive; micro-USB-B for power and computer connectivity<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>GLP<\/th>\n<td class=data last>calibration data for connected pH electrode<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Display<\/th>\n<td class=data last>128 x 64 pixel LCD with backlight<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Battery Type \/ Life<\/th>\n<td class=data last>3.7 VDC Li-polymer rechargeable battery \/ >500 photometric measurements or 50 hours of continuous pH measurement<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Power Supply<\/th>\n<td class=data last>5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Environment<\/th>\n<td class=data last>0 to 50.0\u00a0oC (32 to 122.0\u00a0oF); 0 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Dimensions<\/th>\n<td class=data last>206 x 177 x 97 mm (8.1 x 7.0 x 3.8\u2033)<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Weight<\/th>\n<td class=data last>1.0 kg (2.2 lbs.)<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Photometer\/Colorimeter Light Source<\/th>\n<td class=data last>4 LEDs with 420 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Photometer\/Colorimeter Light Detector<\/th>\n<td class=data last>silicon photodetector<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Bandpass Filter Bandwidth<\/th>\n<td class=data last>8 nm<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Bandpass Filter Wavelength Accuracy<\/th>\n<td class=data last>\u00b11 nm<\/td>\n<\/tr>\n<tr class=odd>\n<th class=label>Cuvette Type<\/th>\n<td class=data last>round, 24.6 mm<\/td>\n<\/tr>\n<tr class=even>\n<th class=label>Number of Methods<\/th>\n<td class=data last>128 max.<\/td>\n<\/tr>\n<tr class=last odd>\n<th class=label>Ordering Information<\/th>\n<td class=data last>HI83308 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"<div id=\"attachment_4069\" style=\"width: 310px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4069\" title=\"multiparameter photometer &amp; ph meter\" class=\"size-medium wp-image-4069 lazyloaded\" data-src=\"https:\/\/www.chemicalplus.co.za\/wp-content\/uploads\/2020\/07\/multiparameter-photometer-ph-meter.jpg.webp\" alt=\"multiparameter photometer &amp; ph meter\" width=\"300\" height=\"300\" src=\"https:\/\/www.chemicalplus.co.za\/wp-content\/uploads\/2020\/07\/multiparameter-photometer-ph-meter.jpg.webp\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/300;\"><noscript><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4069\" title=\"multiparameter photometer &amp; ph meter\" class=\"size-medium wp-image-4069\" src=\"https:\/\/www.chemicalplus.co.za\/wp-content\/uploads\/2020\/07\/multiparameter-photometer-ph-meter.jpg.webp\" alt=\"multiparameter photometer &amp; ph meter\" width=\"300\" height=\"300\" \/><\/noscript><\/p>\n<p id=\"caption-attachment-4069\" class=\"wp-caption-text\">Multiparameter Photometer &amp; pH Meter for Water Conditioning- HI83308-02<\/p>\n<\/div>\n<p>HI83308 is a compact, multiparameter photometer for use in water conditioning applications.<\/p>\n<p>The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.<\/p>\n<p>This meter has 23 different programmed methods measuring 15 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Water conditioning parameters include fluoride, chlorine, ammonia, manganese, copper, iron, silver and zinc.<\/p>\n<p>To save valuable laboratory benchtop space, the HI83308 doubles as a professional pH meter with its digital pH\/temperature electrode input. Now one meter can be used for both photometric and pH measurements.<\/p>\n<div>\n<h3 class=\"spec-header\"><\/h3>\n<table id=\"product-attribute-specs-table-1\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">pH Range<\/th>\n<td class=\"data last\">Photometer: 6.5 to 8.5 pH<br \/>\npH electrode: -2.00 to 16.00 pH<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH Resolution<\/th>\n<td class=\"data last\">Photometer: 0.1 pH<br \/>\npH electrode: 0.01 pH<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">pH Accuracy<\/th>\n<td class=\"data last\">Photometer: \u00b10.1 pH<br \/>\npH electrode: \u00b10.01 pH<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH Calibration<\/th>\n<td class=\"data last\">Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">pH Temperature Compensation<\/th>\n<td class=\"data last\">Automatic (-5.0 to 100.0&nbsp;oC; 23.0 to 212.0&nbsp;oF); limits reduced based on the pH electrode used<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH CAL Check (electrode diagnostics)<\/th>\n<td class=\"data last\">clean electrode and check buffer\/check probe displayed during calibration<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">pH Method<\/th>\n<td class=\"data last\">Photometer: phenol red<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH-mV Range<\/th>\n<td class=\"data last\">\u00b11000 mV<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">pH-mV Resolution<\/th>\n<td class=\"data last\">0.1 mV<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">pH-mV Accuracy<\/th>\n<td class=\"data last\">\u00b10.2 mV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Oxygen, Dissolved<\/h3>\n<table id=\"product-attribute-specs-table-2\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Oxygen, Dissolved Range<\/th>\n<td class=\"data last\">0.0 to 10.0 mg\/L (as O2)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Oxygen, Dissolved Resolution<\/th>\n<td class=\"data last\">0.1 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Oxygen, Dissolved Accuracy<\/th>\n<td class=\"data last\">\u00b10.4 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Oxygen, Dissolved Method<\/th>\n<td class=\"data last\">Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Absorbance<\/h3>\n<table id=\"product-attribute-specs-table-3\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Absorbance Range<\/th>\n<td class=\"data last\">0.000 to 4.000 Abs<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Absorbance Resolution<\/th>\n<td class=\"data last\">0.001 Abs<\/td>\n<\/tr>\n<tr class=\"last odd\">\n<th class=\"label\">Absorbance Accuracy<\/th>\n<td class=\"data last\">+\/-0.003Abs @ 1.000 Abs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Ammonia<\/h3>\n<table id=\"product-attribute-specs-table-4\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Ammonia Range<\/th>\n<td class=\"data last\">Low Range: 0.00 to 3.00 mg\/L<br \/>\nMedium Range: 0.00 to 10.00 mg\/L<br \/>\nHigh Range: 0.0 to 100.0 mg\/L<br \/>\n(all as NH3-N)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Ammonia Resolution<\/th>\n<td class=\"data last\">0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Ammonia Accuracy<\/th>\n<td class=\"data last\">Low Range: \u00b10.04 mg\/L \u00b14% of reading<br \/>\nMedium Range: \u00b10.05 mg\/L \u00b15% of reading<br \/>\nHigh range: \u00b10.5 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Ammonia Method<\/th>\n<td class=\"data last\">Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Chlorine<\/h3>\n<table id=\"product-attribute-specs-table-5\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Free Chlorine Range<\/th>\n<td class=\"data last\">0.00 to 5.00 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Free Chlorine Resolution<\/th>\n<td class=\"data last\">0.01 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Free Chlorine Accuracy<\/th>\n<td class=\"data last\">\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Total Chlorine Range<\/th>\n<td class=\"data last\">0.00 to 5.00 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Total Chlorine Resolution<\/th>\n<td class=\"data last\">0.01 mg\/L<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Total Chlorine Accuracy<\/th>\n<td class=\"data last\">\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=\"last odd\">\n<th class=\"label\">Chlorine Method<\/th>\n<td class=\"data last\">Adaptation of the EPA 330.5 DPD method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Copper<\/h3>\n<table id=\"product-attribute-specs-table-6\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Copper Range<\/th>\n<td class=\"data last\">Low Range: 0.000 to 1.500 mg\/L (as Cu2+)<br \/>\nHigh range: 0.00 to 5.00 mg\/L (as Cu2+)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Copper Resolution<\/th>\n<td class=\"data last\">0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Copper Accuracy<\/th>\n<td class=\"data last\">Low Range: \u00b10.01 mg\/L \u00b15% of reading<br \/>\nHigh Range \u00b10.02 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Copper Method<\/th>\n<td class=\"data last\">Adaptation of the EPA bicinchoninate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Fluoride<\/h3>\n<table id=\"product-attribute-specs-table-7\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Fluoride Range<\/th>\n<td class=\"data last\">0.00 to 2.00 mg\/L (as F-)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Fluoride Resolution<\/th>\n<td class=\"data last\">0.01 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Fluoride Accuracy<\/th>\n<td class=\"data last\">\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Fluoride Method<\/th>\n<td class=\"data last\">Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Iron<\/h3>\n<table id=\"product-attribute-specs-table-8\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Iron Range<\/th>\n<td class=\"data last\">Low Range: 0.000 to 1.600 mg\/L (as Fe)<br \/>\nHigh Range: 0.00 to 5.00 mg\/L (as Fe)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Iron Resolution<\/th>\n<td class=\"data last\">0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Iron Accuracy<\/th>\n<td class=\"data last\">Low Range: \u00b10.01 mg\/L \u00b18% of reading<br \/>\nHigh Range: \u00b10.04 mg\/L \u00b12% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Iron Method<\/th>\n<td class=\"data last\">Low Range: Adaptation of the TPTZ Method<br \/>\nHigh Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Manganese<\/h3>\n<table id=\"product-attribute-specs-table-9\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Manganese Range<\/th>\n<td class=\"data last\">Low Range: 0 to 300 ?g\/L (as Mn)<br \/>\nHigh Range: 0.0 to 20.0 (as Mn)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Manganese Resolution<\/th>\n<td class=\"data last\">1 ?g\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Manganese Accuracy<\/th>\n<td class=\"data last\">Low Range: \u00b110 ?g\/L \u00b13% of reading<br \/>\nHigh Range: \u00b10.2 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Manganese Method<\/th>\n<td class=\"data last\">Low Range: Adaptation of the PAN Method<br \/>\nHigh Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Molybdenum<\/h3>\n<table id=\"product-attribute-specs-table-10\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Molybdenum Range<\/th>\n<td class=\"data last\">0.0 to 40.0 mg\/L (as Mo6+)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Molybdenum Resolution<\/th>\n<td class=\"data last\">0.1 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Molybdenum Accuracy<\/th>\n<td class=\"data last\">\u00b10.3 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Molybdenum Method<\/th>\n<td class=\"data last\">Adaptation of the mercaptoacetic acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Nickel<\/h3>\n<table id=\"product-attribute-specs-table-11\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Nickel Range<\/th>\n<td class=\"data last\">Low Range: 0.000 to 1.000 mg\/L (as Ni)<br \/>\nHigh Range: 0.00 to 7.00 g\/L (as Ni)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Nickel Resolution<\/th>\n<td class=\"data last\">0.001 mg\/L; 0.01 g\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Nickel Accuracy<\/th>\n<td class=\"data last\">Low range: \u00b10.010 mg\/L \u00b17% of reading<br \/>\nHigh Range: \u00b10.07 g\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Nickel Method<\/th>\n<td class=\"data last\">Low Range: Adaptation of the PAN method<br \/>\nHigh Range: Adaptation of the photometric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Nitrate<\/h3>\n<table id=\"product-attribute-specs-table-12\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Nitrate Range<\/th>\n<td class=\"data last\">0.0 to 30.0 mg\/L (as NO3\u2013 N)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Nitrate Resolution<\/th>\n<td class=\"data last\">0.1 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Nitrate Accuracy<\/th>\n<td class=\"data last\">\u00b10.5 mg\/L \u00b110% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Nitrate Method<\/th>\n<td class=\"data last\">Adaptation of the cadmium reduction method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Phosphate<\/h3>\n<table id=\"product-attribute-specs-table-13\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Phosphate Range<\/th>\n<td class=\"data last\">Freshwater<br \/>\nLow Range: 0.00 to 2.50 mg\/L (as PO43-)<br \/>\nHigh range: 0.0 to 30.0 mg\/L(as PO43-)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Phosphate Resolution<\/th>\n<td class=\"data last\">0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Phosphate Accuracy<\/th>\n<td class=\"data last\">Low Range: \u00b10.04 mg\/L \u00b14% of reading<br \/>\nHigh Range: \u00b11 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Phosphate Method<\/th>\n<td class=\"data last\">Low Range: Adaptation of the Ascorbic Acid method<br \/>\nHigh Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Silica<\/h3>\n<table id=\"product-attribute-specs-table-14\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Silica Range<\/th>\n<td class=\"data last\">0.00 to 2.00 mg\/L (as SiO2)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Silica Resolution<\/th>\n<td class=\"data last\">0.01 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Silica Accuracy<\/th>\n<td class=\"data last\">\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Silica Method<\/th>\n<td class=\"data last\">Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Silver<\/h3>\n<table id=\"product-attribute-specs-table-15\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Silver Range<\/th>\n<td class=\"data last\">0.000 to 1.000 mg\/L (as Ag)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Silver Resolution<\/th>\n<td class=\"data last\">0.001 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Silver Accuracy<\/th>\n<td class=\"data last\">\u00b10.020 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Silver Method<\/th>\n<td class=\"data last\">Adaptation of the PAN method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">Zinc<\/h3>\n<table id=\"product-attribute-specs-table-16\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Zinc Range<\/th>\n<td class=\"data last\">0.00 to 3.00 mg\/L (as Zn)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Zinc Resolution<\/th>\n<td class=\"data last\">0.01 mg\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Zinc Accuracy<\/th>\n<td class=\"data last\">\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Zinc Method<\/th>\n<td class=\"data last\">Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"spec-header\"><\/h3>\n<h3 class=\"spec-header\">General Meter<\/h3>\n<table id=\"product-attribute-specs-table-17\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\">\n<col><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">Input Channels<\/th>\n<td class=\"data last\">1 pH electrode input and 4 photometer wavelengths<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH Electrode<\/th>\n<td class=\"data last\">digital pH electrode (not included)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Logging Type<\/th>\n<td class=\"data last\">log on demand with user name and sample ID optional input<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Logging Memory<\/th>\n<td class=\"data last\">1000 readings<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Connectivity<\/th>\n<td class=\"data last\">USB-A host for flash drive; micro-USB-B for power and computer connectivity<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">GLP<\/th>\n<td class=\"data last\">calibration data for connected pH electrode<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Display<\/th>\n<td class=\"data last\">128 x 64 pixel LCD with backlight<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Battery Type \/ Life<\/th>\n<td class=\"data last\">3.7 VDC Li-polymer rechargeable battery \/ &gt;500 photometric measurements or 50 hours of continuous pH measurement<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Power Supply<\/th>\n<td class=\"data last\">5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Environment<\/th>\n<td class=\"data last\">0 to 50.0&nbsp;oC (32 to 122.0&nbsp;oF); 0 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Dimensions<\/th>\n<td class=\"data last\">206 x 177 x 97 mm (8.1 x 7.0 x 3.8\u2033)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Weight<\/th>\n<td class=\"data last\">1.0 kg (2.2 lbs.)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Photometer\/Colorimeter Light Source<\/th>\n<td class=\"data last\">4 LEDs with 420 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Photometer\/Colorimeter Light Detector<\/th>\n<td class=\"data last\">silicon photodetector<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Bandpass Filter Bandwidth<\/th>\n<td class=\"data last\">8 nm<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Bandpass Filter Wavelength Accuracy<\/th>\n<td class=\"data last\">\u00b11 nm<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Cuvette Type<\/th>\n<td class=\"data last\">round, 24.6 mm<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Number of Methods<\/th>\n<td class=\"data last\">128 max.<\/td>\n<\/tr>\n<tr class=\"last odd\">\n<th class=\"label\">Ordering Information<\/th>\n<td class=\"data last\">HI83308 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":50420,"template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[11343,11411],"product_tag":[11487],"class_list":{"0":"post-50376","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-laboratory-scientific-instruments","7":"product_cat-ph-meters-and-conductivity-meters-laboratory-scientific-instruments","8":"product_tag-laboratory-equipmentlaboratory-scientific-instrumentsph-meters-and-conductivity-meters","10":"first","11":"instock","12":"sale","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=\/wp\/v2\/product\/50376","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=\/wp\/v2\/media\/50420"}],"wp:attachment":[{"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=50376"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=50376"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=50376"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/medqpharmaceuticalsupplies.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=50376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}